Product Details
Table 1 Device attributes |
Product Type |
Description |
BOM |
Model |
EarliestSoftware Version |
NE40E-X8A DC |
NE40E-X8A Integrated Chassis DC Components(Including 2 Fan Tray) |
02350AFW |
CR5B0BKP0871 |
V800R006C20 |
NE40E-X8A AC |
NE40E-X8A Integrated Chassis AC Components(Including 2 Fan Tray) |
02350AFX |
CR5B0BKP0872 |
V800R006C20 |
NE40E-X8A HVDC |
NE40E-X8A Integrated Chassis HVDC Components(Including 2 Fan Tray) |
02351CCF |
CR5B0BKP0873 |
V800R009C10
|
Appearance of Huawei NE40E-X8A
Figure 1 Appearance
Figure 2 Components (front view)
1. Rack-mounting ear |
2. ESD jack |
3. Lifting handle |
4. Air intake frame (With air filter) |
5. LPU |
6. SRU |
7. SFU |
8. Switch module |
9. Power monitoring module (PMU) |
10 Power module (PM) |
11. Cabling tray |
12. Power module cover |
Figure 3 Components (rear view)
13. Fan module |
14. ESD jack |
15. Ground terminal |
16. Power entry module (PEM) |
17. Non-lifting handle |
|
|
|
Figure 4 Slot layout
Table 2 Description of slot layout |
Slot Name |
Slot Quantity |
Slot ID |
Remarks |
LPU |
8 |
1 to 8 |
These slots hold LPUs. |
SRU |
2 |
9 to 10 |
These slots hold SRUs. |
SFU |
2 |
11 to 12 |
These slots hold SFUs. |
An interface is numbered in the format of slot number/subcard number/port number.
NOTE:
Slot number: The slots of LPUs are numbered from top to bottom and from left to right (marked on the panel), in the range of 1 to 8.
Subcard number: The subcards are numbered from top to bottom and from left to right, starting from 0. If an LPU does not have any subcard, the subcard number is 0.
Port number: The ports are numbered from top to bottom and from left to right, starting from 0.
Technical Specifications of Huawei NE40E-X8A
Item |
Specification |
Dimensions (H x W x D)
|
●(21 U) 930 mm x 442 mm x 650 mm (36.61 in. x 17.40 in. x 25.59 in.) (Chassis main body)
●(21 U) 930 mm x 442 mm x 750 mm (36.61 in. x 17.40 in. x 29.53 in.) (Dimensions of the chassis body together with cable trays and front and back attachments)
|
Weight (empty) |
●DC: 68.1 kg (150.16 lb) (without filler panels)
●HVDC&AC: 63.7 kg (140.46 lb) (without filler panels)
|
Weight (full configuration) |
●[1T bundle] DC:209 kg (460.85 lb)
●[1T bundle]HVDC&AC:206.5 kg (455.33 lb)
|
Cabinet installation standard |
Can be installed in a standard 19" 800 mm-deep cabinet. A Huawei 2.2 m-high N68E cabinet is used by default. |
Typical power consumption |
●4110 W (fully configured with LPUF-240s)
●4770 W (fully configured with LPUF-480s)
●6520 W (fully configured with LPUI-1Ts)
|
Typical heat dissipation |
●13334.6 BTU/hour (fully configured with LPUF-240s)
●15475.9 BTU/hour (fully configured with LPUF-480s)
●21153.6 BTU/hour (fully configured with LPUI-1Ts)
|
DC input voltage |
●input voltage range: –40 V to –72 V
●input rated voltage: –48 V/ –60 V
|
AC input voltage |
●input voltage range: 180 V to 264 V
●input rated voltage: 200 V to 240 V
|
HVDC input voltage |
●input voltage range: 192 V to 400 V
●input rated voltage: 240 V/380 V
|
MTBF |
22.32 years |
MTTR |
0.5 hours |
Availability |
0.999997443 |
Slot quantity |
12 |
Redundant MPUs |
1:1 |
Redundant Switch fabrics |
3+1 |
Redundant fans
|
●[1T bundle] 3 assemblies in support for proper fan operation in case of a single fan failure for a short period at 40°;C (104°;F) |
Redundant power supply |
●[1T bundle] DC: 5+1
●[1T bundle] HVDC&AC: 4+4
|
Forwarding performance |
2880 Mpps (LPUF-240) |
Switching capacity |
25.16 Tbps (LPUI-1T) |
Operating temperature
|
●Long-term: 0°;C to 45°;C (32°;F to 113°;F)
●Short-term: –5°;C to +55°;C (23°;F to131°;F)
●Remark: Restriction on the temperature variation rate: 30°;C/hour (86°;F/h)
|
Storage temperature |
–40°;C to +70°;C (–40°;F to +158°;F) |
Relative operating humidity |
●Long term: 5% to 85% RH, non-condensing
●Short term: 5% to 95% RH, non-condensing
|
Relative storage humidity |
5% to 95% RH, non-condensing |
Long-term operating altitude
|
<= 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature of the NEU100 must decrease by 1°;C [33.8°;F] for every 220 m [721.78 ft.].) |
Storage altitude |
Less than 5000 m (16404 ft.) |
http://www.uonel-telecom.com/